dc.description.abstract This paper responds to the EU goals of decarbonization with solar energy leading to fifth-generation district energy systems (5DE). The dilemma of low-exergy (low-temperature) district heating systems with renewable and waste thermal sources and the temperature-incompatibility of the current comfort heating equipment demanding higher supply temperatures is addressed. Until innovative, low-exergy equipment and higher-exergy solar photo-voltaic-heat systems are developed, various methods of optimum temperature peaking and existing equipment oversizing are presented. Central temperature peaking at the plant site and the individual prosumer buildings are compared. A case study is presented, which involves an individually optimized solar prosumer building with an optimum mix of heat pump oversizing and commercial radiator oversizing. Results show that CO2 emissions responsibility-based optimum mix compared to economy-based optimum mix reduces the responsibility by 30%. This analysis was repeated by cascading two smaller heat pumps instead of a larger one to increase the overall COP. This change further improved the solution by 4% points. Results have also been compared to a modified case where cascaded heat pumps are coupled with low-exergy heat pipe radiators. This coupling resulted in much more improvement by an additional 52% points. The paper concludes that the key is low-exergy heating and cooling equipment. Then the fifth-generation district energy systems with supply temperatures as low as 320 K (47°C) and return temperatures as low as 300 K (27°C) will be possible with renewable and waste energy sources if the one-way distance between the plant and the district is not more than 1.6x10-5 km/kW times the thermal capacity of the district raised to a power of 1.5. © Published under licence by IOP Publishing Ltd. en_US
dc.language.iso en en_US
dc.title Exergy-rational utilization of solar energy with advanced PVT systems and heat pipe technology in 100% renewable cities en_US
dc.type Other en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account